VERSION 34 @! @! Stage 5 Project Data Update Package for Project [#] - Energization [#] @! ======================== @! RAW AND SEQUENCE DATA @! Created by [Engineer’s Name] at [Company Name] for [Client Name if consultant] on [Date] @! BAT_PURGBRN,123,456,'10' RDCH 1 0 / END OF SYSTEM-WIDE DATA, BEGIN BUS DATA @! I,'NAME', BASKV, IDE,AREA,ZONE,OWNER, VM, VA, NVHI, NVLO, EVHI, EVLO 1111,'BUS1', 138.0000,1, 4, 1, 12,1.00871, 27.3496,1.10000,0.90000,1.10000,0.90000 2222,'BUS2', 138.0000,1, 4, 1, 12,1.00743, 27.1717,1.10000,0.90000,1.10000,0.90000 3333,'BUS3', 69.0000,1, 4, 1, 12,1.01330, 28.3619,1.10000,0.90000,1.10000,0.90000 123,'BUS4', 69.0000,1, 4, 1, 12,1.01330, 28.3619,1.10000,0.90000,1.10000,0.90000 0 / END OF BUS DATA, BEGIN LOAD DATA 0 / END OF LOAD DATA, BEGIN FIXED SHUNT DATA 0 / END OF FIXED SHUNT DATA, BEGIN GENERATOR DATA 0 / END OF GENERATOR DATA, BEGIN BRANCH DATA @! I, J,'CKT', R, X, B, 'N A M E', RATE1, RATE2, RATE3, RATE4, RATE5, RATE6, RATE7, RATE8, RATE9, RATE10, RATE11, RATE12, GI, BI, GJ, BJ,STAT,MET, LEN, O1, F1, O2, F2, O3, F3, O4, F4 123,3333,'01', 5.31340E-4, 4.47300E-3, 0.00012,'BRANCH1', 150.00, 163.00, 150.00, 163.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00000, 0.00000, 0.00000, 0.00000,1,2, 0.56, 12,1.0000 1111,2222,'02', 2.52048E-3, 1.55272E-2, 0.00445,'BRANCH2', 196.00, 215.00, 196.00, 215.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00000, 0.00000, 0.00000, 0.00000,1,2, 7.00, 12,1.0000 0 / END OF BRANCH DATA, BEGIN SYSTEM SWITCHING DEVICE DATA 0 / END OF SYSTEM SWITCHING DEVICE DATA, BEGIN TRANSFORMER DATA @! I, J, K,'CKT',CW,CZ,CM, MAG1, MAG2,NMETR, 'N A M E', STAT,O1, F1, O2, F2, O3, F3, O4, F4, 'VECGRP', ZCOD @! R1-2, X1-2, SBASE1-2, R2-3, X2-3, SBASE2-3, R3-1, X3-1, SBASE3-1, VMSTAR, ANSTAR @!WINDV1, NOMV1, ANG1, RATE1-1, RATE1-2, RATE1-3, RATE1-4, RATE1-5, RATE1-6, RATE1-7, RATE1-8, RATE1-9, RATE1-10, RATE1-11, RATE1-12,COD1,CONT1, RMA1, RMI1, VMA1, VMI1, NTP1,TAB1, CR1, CX1, CNXA1 @!WINDV2, NOMV2, ANG2, RATE2-1, RATE2-2, RATE2-3, RATE2-4, RATE2-5, RATE2-6, RATE2-7, RATE2-8, RATE2-9, RATE2-10, RATE2-11, RATE2-12,COD2,CONT2, RMA2, RMI2, VMA2, VMI2, NTP2,TAB2, CR2, CX2, CNXA2 @!WINDV3, NOMV3, ANG3, RATE3-1, RATE3-2, RATE3-3, RATE3-4, RATE3-5, RATE3-6, RATE3-7, RATE3-8, RATE3-9, RATE3-10, RATE3-11, RATE3-12,COD3,CONT3, RMA3, RMI3, VMA3, VMI3, NTP3,TAB3, CR3, CX3, CNXA3 2222, 456, 0,'T1', 1, 1, 1, 3.40000E-4,-3.20000E-4,1,'TRANSFORMER1',1, 12,1.0000, 0,1.0000, 0,1.0000, 0,1.0000,'YNa0 ' 1.74000E-3, 8.57200E-2, 100.00 1.00000, 0.000, 0.000, 50.00, 60.00, 70.00, 80.00, 90.00, 100.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00,-1, 456, 1.10000, 0.90000, 1.10000, 0.90000, 33, 0, 0.00000, 0.00000, 0.000 1.00000, 0.000 1111,3333, 0,'T2', 1, 1, 1, 3.30000E-4,-3.40000E-4,2,'TRANSFORMER2',1, 12,1.0000, 0,1.0000, 0,1.0000, 0,1.0000,'YNyn0 ' 1.75000E-3, 8.57200E-2, 100.00 1.00000, 0.000, 0.000, 50.00, 60.00, 70.00, 80.00, 90.00, 100.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00,-1, 3333, 1.10000, 0.90000, 1.10000, 0.90000, 33, 0, 0.00000, 0.00000, 0.000 1.00000, 0.000 0 / END OF TRANSFORMER DATA, BEGIN AREA DATA 0 / END OF AREA DATA, BEGIN TWO-TERMINAL DC DATA 0 / END OF TWO-TERMINAL DC DATA, BEGIN VSC DC LINE DATA 0 / END OF VSC DC LINE DATA, BEGIN IMPEDANCE CORRECTION DATA 0 / END OF IMPEDANCE CORRECTION DATA, BEGIN MULTI-TERMINAL DC DATA 0 / END OF MULTI-TERMINAL DC DATA, BEGIN MULTI-SECTION LINE DATA 0 / END OF MULTI-SECTION LINE DATA, BEGIN ZONE DATA 0 / END OF ZONE DATA, BEGIN INTER-AREA TRANSFER DATA 0 / END OF INTER-AREA TRANSFER DATA, BEGIN OWNER DATA 0 / END OF OWNER DATA, BEGIN FACTS DEVICE DATA 0 / END OF FACTS DEVICE DATA, BEGIN SWITCHED SHUNT DATA 0 / END OF SWITCHED SHUNT DATA, BEGIN GNE DATA 0 / END OF GNE DATA, BEGIN INDUCTION MACHINE DATA 0 / END OF INDUCTION MACHINE DATA, BEGIN SUBSTATION DATA 0 / END OF SUBSTATION DATA Q RESQ 1 1, 34 0 / END OF SYSTEM-WIDE DATA, BEGIN GENERATOR DATA 0 / END OF GENERATOR DATA, BEGIN LOAD DATA 0 / END OF LOAD DATA, BEGIN ZERO SEQ. NON-TRANSFORMER BRANCH DATA @!! I, J,'ICKT', RLINZ, XLINZ, BCHZ, GI, BI, GJ, BJ, IPR,SCTYP 123,3333,'01', 4.64100E-3, 1.56040E-2, 0.00005, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0,0 1111,2222,'02', 8.22306E-3, 4.26644E-2, 0.00236, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0,0 0 / END OF ZERO SEQ. NON-TRANSFORMER BRANCH DATA, BEGIN ZERO SEQ. MUTUAL DATA 0 / END OF ZERO SEQ. MUTUAL DATA, BEGIN ZERO SEQ. TRANSFORMER DATA @!! I, J, K,'ICKT',CZ0,CZG,CC, RG1, XG1, R01, X01, RG2, XG2, R02, X02, RNUTRL, XNUTRL @!! I, J, K,'ICKT',CZ0,CZG,CC, RG1, XG1, R01, X01, RG2, XG2, R02, X02, RG3, XG3, R03, X03, RNUTRL, XNUTRL 2222, 456, 0,'T1',1,1, 8, 6.34780E-1, 1.45233E+0, 1.75000E-3, 8.13300E-2,-4.61246E+0,-3.79880E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0 3333,1111, 0,'T2',1,1, 8, 6.42670E-1, 1.41496E+0, 1.82000E-3, 8.12200E-2,-4.35908E+0,-3.48880E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0, 0.00000E+0 0 / END OF ZERO SEQ. TRANSFORMER DATA, BEGIN ZERO SEQ. SWITCHED SHUNT DATA 0 / END OF ZERO SEQ. SWITCHED SHUNT DATA, BEGIN ZERO SEQ. FIXED SHUNT DATA 0 / END OF ZERO SEQ. FIXED SHUNT DATA, BEGIN INDUCTION MACHINE DATA 0 / END OF INDUCTION MACHINE DATA, BEGIN NON CONVENTIONAL SOURCE FAULT CONTRIBUTION DATA 0 / END OF NON CONVENTIONAL SOURCE FAULT CONTRIBUTION DATA Q